Bug-fixes in HyWorks v3.6-SP1 Hotfixes
HyWorks v3.6-SP1-Hotfix1.3
The following bugs have been fixed in the HyWorks v3.6-SP1-Hotfix1.3 release:
| Bug ID | Description |
|---|---|
| 60803 | Azure connector is going into an unreachable state intermittently with HyWorks Controller v3.6-SP1 or v3.6-SP1 + Hotfix1/ Hotfix1.1/Hotfix1.2. The issue is fixed in v3.6-SP1-HF1.3 and must be applied on top of v3.6-SP1 (or v3.6-SP1+HF1.0/HF1.1/HF1.2) for deployments using Azure as a connector. |
| 60975 | Logging in to the HyWorks Management Console fails for a user with a password longer than 43 characters with the error: Password out of range. The password character limit has been updated in HF1.3 to 127 characters. |
HyWorks v3.6-SP1-Hotfix1.2
The following bugs have been fixed in the HyWorks v3.6-SP1-Hotfix1.2 release:
| Bug ID | Description |
|---|---|
| 60254 | A rare race condition caused VMs to enter a missing state, sometimes leading to the unintended deletion of VMs during parallel pool operations involving VM delete actions, such as pool recompose. Fixed in v3.6-SP1-HF1.2. |
| 60239 | Cloning failed with the Nutanix connector (PC 7.0+) due to an object reference error. Fixed in v3.6-SP1-HF1.2. |
HyWorks v3.6-SP1-Hotfix1.1
The following bugs have been fixed in the HyWorks v3.6-SP1-Hotfix1.1 release:
HyWorks Controller and Server-side Modules
| Bug ID | Description |
|---|---|
| 58634 | Email Address Field on HyLabs Participant screen for a user with a custom role was editable, but always reverted to the email address fetched from the AD. This issue has been fixed in this release. The field is no longer editable by users other than the HyLabs admin. |
| 56948 | The HyPrint option in the connection profile did not have appropriate help-text. The help text has been improved for better guidance. |
| 54916 | Azure Ubuntu VM reservation is deployed but is stuck in the Preparation state. This issue occurs because the power-on operation failed for all the VMs. The issue is fixed in HyWorks v3.6-SP1-HF1.1 release. Now HyWorks waits for a timeout during the power operation; if it fails, the reservation will still move to the next state. |