Endpoint Management
Configuration Name | Description | Default Value | Tag |
---|---|---|---|
Controller Discovery | If the value is set as true then HyDesk can discover HyWorks Controller in the network. This is also controlled from System > Service config > Discovery Settings. Broadcast port is used as configured in Advance config > Controller Discovery Port (default: 39003) |
False | - |
In session HyDesk heartbeat timeout multiplier | HyDesk Heartbeat interval increases with this set multiplier. | 3 | Heartbeat |
Deliver Applications to Client Version Onwards | Client with version and above supports Applications delivery | 300000 | - |
Define/Specify the device time zone | Specify the timezone to be enforced on HyDesk. | IST | - |
Enforce time zone | Enforce time zone to HyDesk. Expected values: True Or False, Default value: False | False | - |
Stop Controller-HyDesk Date Sync | If this is set as true, then HyWorks Controller will stop sending the Date to HyDesk on the registration call, and HyDesk will stop syncing the date with the controller. | False | HyDesk |
Heartbeat Interval | All endpoints uvse this interval to communicate with the HyWorks Controller; any relevant configurations on endpoints can be set using this heartbeat interval. In large deployments with too many desktop clients, the heartbeat interval can be increased to improve the performance overhead of processing heartbeats from too many endpoints. Note: Increasing heartbeat interval causes longer gaps in communication with endpoints and thus any settings changed on the controller will take effect as per the configured interval. |
40 | Heartbeat, Interval |
In Session HyDesk Heartbeat Timeout Multiplier | With user-logged-in heartbeats are also used this configuration to increase default heartbeat time, which means if a device with no user logged-on sends a heartbeat in 40 seconds, the same device with user logged-on will send a heartbeat in 40 * 3 (Consider multiplier is set as 3) = 120 seconds. | 3 | Heartbeat |
Heartbeats Allowed to be missed | This value is configured number of times a heartbeat is missed allowed, beyond that HyDesk is marked as disconnected. | 3 | Heartbeat |
TCP user timeout | The TCP user timeout controls how long transmitted data may remain unacknowledged before a connection is forcefully closed. Value in Second, Default value is 9. | 9 | RDP |
KeepAlive interval | Keepalive interval is the duration between two successive keepalive retransmissions if acknowledgment of the previous keepalive transmission is not received. Value in Second, Default value is 2. | 2 | RDP |
KeepAlive count | Keepalive count is the number of retransmissions to be carried out before declaring that a remote connection is not available. Value in Second, Default value is 3. | 3 | - |
KeepAlive idle | Keepalive Idle is the duration between two keepalive transmissions in idle condition. Value is in Seconds, Default value is 5 seconds. | 5 | RDP |
Disable HyDesk Activity Monitoring | By default, endpoints send timer details if any user activities are there or not, but in cases where the user has logged in, active on the desktop but not accessing any desktops/ applications. In such cases, HyWorks uses this flag to determine whether information sent by endpoints about the user being active should be considered. It should be kept as true as HyWorks will then ignore user activeness details by clients with no desktops or apps accessed. | True | - |