Device life span |
Number of days, after which inactive registered endpoints will be automatically deleted. Enter zero to never delete the devices. The minimum number of days to delete the device should be 30. |
30 |
- |
Show Device Alert Counts On Dashboard |
Show device alert counts on the dashboard. True = show and False = Do not show. |
true |
Performance |
User life span |
Number of days, after which inactive users will be automatically deleted. Enter zero to disable automatic user deletion. The minimum number of days to delete the users should be 30. |
30 |
- |
Controller Session Monitoring |
This flag is used to enable Controller Session logging. After enabling this flag, it will add extra logs for user login and connect desktop and application. |
False |
Controller |
Controller Session Monitoring URL |
This URL is used to set the Controller Session Monitoring Queue connection string (e.g. username:password@IP_ADDRESS:PORT//). |
amqp://nils:nils@ 172.17.1.183:5672// |
- |
UDP Log Listener Port |
This port is used to process logs via UDP. Controller/HyLabs logger sends logs on this port. |
38872 |
- |
Monitoring Service Path |
The controller fetches monitoring data from this URL IP address replaced at runtime. |
True |
Path |
Controller Discovery Port |
The client sends a UDP payload to this port to discover the Controller. Applicable when Controller discovery setting is enabled. |
39003 |
- |
Export CSV Pagination Count |
This is the number of entries that will be fetched from the database at a time. The default value is 0, which indicates all the data will be fetched in a single call from the database. |
0 |
Export CSV |
Enable Tracing |
Enables log tracing. Recommended to set the value as False. If enabled, it will have a performance impact. |
False |
- |
Memory Monitoring Enabled |
The Controller Memory Optimizer optimizes the memory used by the controller after the Controller Memory Optimizer Interval. Recommended to set the value as True. |
True |
Logging |
Controller Memory Optimizer Interval |
Controller Memory Optimizer - optimizes memory used by the controller after this Interval. (Minimum value 900 seconds- 15 mins) |
900 |
- |
Controller Session Monitoring Interval |
This value is used to define the Controller Session Monitoring interval (in minutes). |
15 |
Interval |
Controller Memory Optimizer Threshold |
If controller memory exceeds this value then the controller’s memory utilization will be optimized to default 5000 MB (5 GB). Value in MB. |
5000 |
- |
Maximum concurrent Thread for job |
Max number of concurrent threads can use add/update and get job status. It requires the HyWorks controller service to restart to get the changes in effect. |
50 |
Controller |
Number of job read |
This is the number of jobs read from the database before initiation. This count is applicable for power operation and deleting DVM jobs. |
100 |
Controller |
Control Single Desktop Auto Launch |
Controls automatic launch of the desktop session on the client. Applicable for single desktop assignments. Set this as true to launch the desktop automatically, and set it as false to not launch the desktop automatically after a successful login. |
True |
- |
Job pickup interval |
Interval (sec) to check new power operation job is created, then it will pick and execute the job, the default value is 20 seconds. |
20 |
Controller |
Job history cleanup interval |
Interval (min) to clean up dead jobs such as completed, and failed from the database. |
5 |
Controller |
Disable RDP port ping for Session host machine |
This flag is used to ping the provider in a test connection for Windows and Linux session host server. True = stop ping, False = start ping. |
False |
Controller |
Max Recent Applications Count |
The number of applications will be shown as recent applications. |
5 |
- |
Enable TSE Support |
Set false in non-TSE deployments for better performance. |
False |
Performance |
Running job status update interval |
Interval (sec) to check power operation and desktop clone jobs with hypervisor and update job status in the database. |
5 |
Controller |
WAN RDP Proxy Control |
If the User wants to access Desktop and Applications then WAN RDP needs to be enabled. (For non-HySecure deployment). |
True |
Control |
Resource Status Monitor Control |
Resource Status Monitor checks Endpoint status, Authentication/Authorization connection status, Session Provider connection status, and User Session. Recommended to set the value as True. |
True |
Control |
Log Remover Control |
Log Remover Controls will check the log count and remove logs if it reaches the threshold. Recommended to set the value as True. |
True |
- |
Log Remover Threshold |
If the log entries exceed this value then it will remove logs in the first in first out (FIFO) fashion. The default value is 500000 log entries. |
500000 |
Interval, Logging |
Log Remover Interval |
Controller Log Remover - Check and remove logs after this Interval. (Minimum value 3600 seconds- 1 hour). |
3600 |
- |
SRMS listing endpoints |
LISTING API Endpoint URL of Session Recording Management System with port. Localhost must be replaced by the IP address of SRMS. |
https://localhost:38892 |
SRMS |
SRMS streaming endpoints |
STREAMING API Endpoint URL of Session Recording Management System with port. Localhost must be replaced by the IP address of SRMS. |
https://localhost:38893 |
SRMS |
SRMS aggregator endpoints |
AGGREGATOR API Endpoint URL of Session Recording Management System with port. Localhost must be replaced by the IP address of SRMS. |
https://localhost:38893 |
SRMS |