SSH Client |
HySecure Gateway |
Secure Shell access |
22 |
TCP |
Yes |
Yes |
SSH access to the HySecure gateway will not work. |
HySecure Client |
HySecure Gateway |
Secure Gateway access |
443 |
TCP |
Yes |
Yes |
User login and Management Console access will not work |
HySecure Active Cluster Manager |
HySecure Standby Cluster Manager |
Cluster information |
939 |
UDP |
No |
Yes |
Cluster information will not be shared among nodes, Node synchronization will fail. |
HySecure Active Cluster Manager |
HySecure Gateway Real Node |
Cluster information |
939 |
UDP |
No |
Yes |
Cluster information will not be shared among nodes; Node synchronization will fail. |
HySecure Standby Cluster Manager |
HySecure Active Cluster Manager |
Cluster information |
939 |
UDP |
No |
Yes |
Cluster information will not be shared among nodes; Node synchronization will fail. |
HySecure Gateway Real Node |
HySecure Active Cluster Manager |
Cluster information |
939 |
UDP |
No |
Yes |
Cluster information will not be shared among nodes; Node synchronization will fail. |
HySecure Gateway All Nodes |
HySecure Active Cluster Manager |
Database access |
3306 |
TCP |
No |
Yes |
HySecure gateway core engine will not work. |
HySecure Management Console |
HySecure Active Cluster Manager |
Load Balancer configuration |
3636 |
TCP |
No |
Yes |
Load Balancer configuration will not be editable/readable from the Management Console. |
HySecure Management Console |
Internal Web Server |
HySecure Management |
4001 |
TCP |
No |
Yes |
HySecure Management Console will not load. |
HySecure Standby Cluster Manager |
HySecure Active Cluster Manager |
Logs Synchronization |
4002 |
UDP |
No |
Yes |
Logs synchronization will not work amongst the cluster. |
HySecure Gateway Real Node |
HySecure Active Cluster Manager |
Logs Synchronization |
4002 |
UDP |
No |
Yes |
Logs synchronization will not work amongst the cluster. |
HyLite Portal |
Internal Remote Access engine |
HTML5 Remote Application Access |
4822 |
TCP |
No |
Yes |
RDP-based application access through the HyLite Portal will not work. |
HySecure Active Cluster Manager |
HySecure Gateway Nodes |
Files Synchronization |
5536 |
TCP |
No |
Yes |
Configuration synchronization will not work amongst the cluster. |
HySecure Gateway |
HySecure Gateway (Self) |
SAML and FIDO based Authentication |
8000 |
TCP |
No |
Yes |
SAML and FIDO based authentication will not work |
HyLite Portal |
HySecure Gateway (Self) |
HyLite Portal |
9000 |
TCP |
No |
Yes |
HyLite Portal will not work. |
HySecure Gateway |
Accops Reporting Server |
Metric Beat |
9264 |
TCP |
No |
Yes |
Log synchronization between the HySecure gateway to the Accops Reporting Server (ARS) server will not work. |
HySecure Client |
HySecure Active Cluster Manager |
Remote Meeting |
51234 |
TCP |
No |
Yes |
Remote meeting application will not work. |
HyLite Portal |
Internal Remote Access engine |
HTML5 Remote Application access |
8000, 9091 |
TCP |
No |
Yes |
RDP-based application will not work through the HyLite Portal. |